Contents of this page
Is my house suitable for a heat pump?
Many existing buildings can be heated well with a heat pump, older houses too. What matters is not the year of construction, but how much heat the house needs on cold days and at what temperature the radiators can deliver this heat. The lower the flow temperature needed, the more efficiently the heat pump works.
In the consultation we therefore check:
- the heat demand (heat load) of your house,
- the flow temperature needed and the size of the existing radiators,
- the condition of the building envelope and sensible measures before replacing the heating,
- Installation location, noise and space for the storage tank,
- Hot water demand and electrical connection.
Which types of heat pumps are there?
Air-to-water heat pump
Uses the outside air as a heat source. The most common type in existing buildings because no drilling or earthworks are needed. Location and noise protection must be planned well.
Brine-to-water heat pump
Uses ground heat via probes or collectors. Efficient, but involves higher development costs and permits.
Water-to-water heat pump
Uses groundwater. Very efficient, but requires suitable groundwater conditions and a water-law permit.
Hybrid solutions
Combination of a heat pump and the existing boiler for the coldest days. Can be a transitional solution; the legal requirements for the share of renewable energy must be observed.
Heat load and correct sizing
The heat load states how much heating power your house needs on the coldest design day. It is calculated room by room according to the standard DIN EN 12831. A heat pump that is too large cycles often, works less efficiently and wears out faster. One that is too small needs a lot of electricity for the immersion heater on cold days.
A good indication for plausibility is past consumption: gas or oil bills show how much heat the house actually needs.
Flow temperature and radiators
The flow temperature is the temperature of the heating water flowing to the radiators. Many older systems run at 60 to 70 °C, often more than necessary. Heat pumps work most efficiently at low flow temperatures; values around 35 to 50 °C are ideal.
Whether that is enough in your house depends on the size of the radiators relative to the heat demand of the rooms. Often it is enough to replace individual radiators instead of installing underfloor heating. A simple practical test: lower the flow temperature step by step in winter and watch whether all rooms stay warm.
This includes hydraulic balancing according to method B, so that every radiator gets the right amount of water. How flow temperature and radiator size are related is explained in detail in the chapter on flow temperature in the PV & Heat Pump Handbook.
COP, SCOP and SPF explained simply
- COP (coefficient of performance)
- Ratio of heat delivered to electricity used at a standardised test point. A COP of 4 means that 1 kWh of electricity becomes 4 kWh of heat, but only under laboratory conditions.
- SCOP (seasonal coefficient of performance)
- Calculated average over a typical heating season according to a standard. Better for comparison than the COP, but not yet a measured value from your house.
- SPF (seasonal performance factor)
- The efficiency actually measured over a year in your house: heat delivered divided by electricity used. It determines your running costs.
Estimate electricity consumption and running costs
A first estimate is simple: heat demand divided by the expected seasonal performance factor gives the electricity consumption. Example: a house with a heat demand of 20,000 kWh a year and an SPF of 3.5 needs about 5,700 kWh of electricity. Multiplied by your electricity price, possibly a cheaper heat pump tariff, this gives the heating electricity costs.
In the consultation we calculate with your consumption data and realistic assumptions for the SPF, and compare with the costs of your current heating, including the uncertainties of energy prices and the CO₂ price.
Compare modernisation options technically and economically
Immediate replacement is not always the best solution. Possible routes include: the heat pump now with some radiators replaced, insulation first and then a smaller heat pump, a hybrid solution as an intermediate step, or optimising the existing heating until the planned replacement. We compare the options by investment, funding, running costs and the requirements of the German Buildings Energy Act (GEG).
Checking heating quotes
Do you already have quotes from heating installers? We check them for you: does the output match the heat load, is a heat load calculation included, are hydraulic balancing, storage, electrical work and commissioning covered, and are the quotes comparable? Choosing the company remains your decision.
Funding routes for replacing the heating
Information checked on . Funding conditions change; the information from BAFA and KfW is authoritative.
Installing a heat pump in an existing building is subsidised by KfW under the Federal Funding for Efficient Buildings. The funding consists of several components that can depend on the timing, the type of the old heating system and income. Because rates and conditions change step by step in 2026 and 2027, we deliberately do not give percentages here. You can find the current status at KfW; we check it for your project in our conversation.
Important: the funding application must usually be made before you sign a contract. So clarify funding early.
Who does what? Consultation, planning, installation
| Task | Responsible |
|---|---|
| Consultation, suitability check, comparison of options | SigmaEnergie |
| Assessment of quotes | SigmaEnergie |
| Heat load calculation and specialist planning | SigmaEnergie |
| Installation, hydraulic balancing, commissioning | Licensed heating contractor |
| Electrical connection, meter, registration with the grid operator | Registered electrical contractor |